Hello, my name is Scott Corum. Good afternoon. I am with Spring Foam Attic Fire Protection and Fire Alarm. Today, we're going to go through the basic operation of an electric fire pump. We'll also run through the maintenance and startup and shutdown procedures of the fire pump. What we have here today is our electric fire pump. We'll go through all the different valves that work with this fire pump. We've got a maintenance pump, which we'll consider as our Jockey pump. We also have our Jockey pump controller and our fire pump controller. We'll run through all these different tests and start off our fire pump. We have signage here to help us visually identify different components. The supply control valve is the main valve for the fire pump, coming from the underground. If we need to do any other type of work on this, we can shut the water off using this valve. We also have bypass valves and control valves, which will remain in the open position. This is in case our fire pump doesn't come on or is not working. City water can still flow through the bypass and reach the electric fire pump. For our Jockey pump, which is also connected to the underground, we have a supply valve and a discharge valve. To work on any part of the fire pump or the Jockey pump, we would close both the supply and discharge valves for the pumps. Throughout this presentation, we'll be looking at two sets of pressure gauges. The suction valve gauge will show us negative 30 if we start sucking the city water dry, up to 300 psi. The discharge valve gauge will show the pressure of the fire pump, which will be around 190 psi. These two gauges will help...
Award-winning PDF software
Nfpa 72 inspection and testing 2024 Form: What You Should Know
NFPA 72.4, Fire Alarm Procedures and NFPA 72.4M, Fire Alarm Systems. These standards cover the entire fire alarm component, including testing of fire alarm systems in conjunction with a specific type of alarm. Prerequisites Before using the fire alarm system inspection form, make sure that you have: Read and understood the rules of the state where that alarm is used (most states require a permit to sell alarm systems with less than the minimum number required for the state), and Have read and understood the NFPA 72.4 standards (if a permit is required by the state before the alarm will be installed). Note: Please read the following before you start your inspections. I. Testing of Fire Alarm Systems 1. Inspection, Testing and Maintenance Before testing a fire alarm system (furnace or smoke detector system), makes sure that it is working properly and its components are functioning as intended. Make sure that the alarm will work in a protected environment. Make sure that all fire controls are in their correct positions for the fire alarm system (fire sprinkler valves should be in the open position). If your fire alarm is installed, make sure that it still functions properly (make sure it's working according to the guidelines of the state where it will be installed). A. Testing the Fire Alarm System A.1. Ensure a Protection Rating of No Alarm. You should not test a fire alarm system without having: A.2. Ensure Alarm-Activated Alarms do not Respond When an Outside Deafening Sound is Heard. If an alarm-activated alarm (with activation codes such as UL 516C, UL 616C and other alarm-activated alarms not identified on this form) does not respond properly to a loud sound, you should test with an outside deafening sound or a test alarm. If testing a fire alarm is required, a test alarm (see A.4) can be used. In testing with an outside deafening sound, make sure the alarm system remains functional. Make sure the alarm does not stop working entirely, even when the loud sound is turned off. A.3. Ensure the Alarm Alarms on an Alarm System are Responsive. If the fire alarm alarm alarm systems on your building respond properly to an alarm, make sure that a protection rating of no alarm is maintained. This protection rating should be checked annually.
online solutions help you to manage your record administration along with raise the efficiency of the workflows. Stick to the fast guide to do NFPa Fire alarm System Record Of Completion, steer clear of blunders along with furnish it in a timely manner:
How to complete any NFPa Fire alarm System Record Of Completion online: - On the site with all the document, click on Begin immediately along with complete for the editor.
- Use your indications to submit established track record areas.
- Add your own info and speak to data.
- Make sure that you enter correct details and numbers throughout suitable areas.
- Very carefully confirm the content of the form as well as grammar along with punctuational.
- Navigate to Support area when you have questions or perhaps handle our assistance team.
- Place an electronic digital unique in your NFPa Fire alarm System Record Of Completion by using Sign Device.
- After the form is fully gone, media Completed.
- Deliver the particular prepared document by way of electronic mail or facsimile, art print it out or perhaps reduce the gadget.
PDF editor permits you to help make changes to your NFPa Fire alarm System Record Of Completion from the internet connected gadget, personalize it based on your requirements, indicator this in electronic format and also disperse differently.